Cryogenic Valve
Home < PRODUCTS < Cryogenic Valve

Cryogenic Service Valve

- Cryogenic Gate Valve
- Cryogenic Globe Valve
- Cryogenic Swing Check Valve

  • CRYOGENIC SERVICE VALVE
APPLIED PART SPECIFICATION
PRESSURE RATING ASME B16.34
FACE TO FACE (END TO END) ASME B16.10
FLANGE DIMENSION ASME B16.5
TESTING BS 6364
BONNET BOLT ASTM A320
BONNET NUT ASTM A194
MARKING SYSTEM MSS-SP-25
WALL THICKNESS HEAVY WALL
AS PER EACH SPEC.
  • CRYOGENIC VALVE PRODUCTION "BS6364/MSS SP-134"
PARTSTAINLESS STEEL VALVESNICKEL BASE ALLOY
MAINCF8MCF8CN7MMONEL
STANDARD TRIM 316 304 316L 304L
BODY A351-CF8M A351-CF8 A351-CF3M A351-CF3
SEAT-RING A479-316+ST¡¯L A479-304+ST¡¯L A479-316L+ST¡¯L A479-304L+ST¡¯L
WEDGE A351-CF8M+ST¡¯L A351-CF8+ST¡¯L A351-CF3M+ST¡¯L A351-CF+ST¡¯L
STEM/HINGE PIN A479-316 A479-304 A479-316L A479-304L
GASKET AS ORDERED
BONNET/COVER A351-CF8M A351-CF8 A351-CF3M A351-CF3
BONNET BOLT A320-B8
BONNET NUT A194-8
BACK SEAT-RING A479-316 A479-304 A479-316L A479-304L
GLAND PACKING AS ORDERED
PACKING GLAND A351-CF8M A351-CF8 A351-CF3M A351-CF3
GLAND FLANGE A351-CF8
YOKE SLEEVE A439-D2C
HANDWHEEL A536
  • STANDARD PRODUCTION SPECIFICATION
  • BODY
  • Body is made in cast and designed according to HLC¡¯s design program and relevant specifi cations. For cryogenic service, it¡¯s made in cast of Austenitic Stainless Steel to have higher impact strength, minimum heat loss and protection against corrosion.
  • SEAT SURFACE
  • Basically, HLC is supplying seal welded seat ring type with Stellite 6 overlay. but it¡¯s possible with integral seat overlaid Stellite 6. To prevent galling and seizing in low temperature, Stellite 6 overlay is recommended for Wedge seat surface. All base metal of seat ring and wedge or disc are followed trim material specifi ed with Austenitic stainless steel. As requirement, it can be equipped with PTFE or other soft material insert seat type to have tight off.
  • BONNET TYPE FOR GATE & GLOBE VALVE
  • HLC is supplying extended bonnet type having enough height to protect gland packing so that it prevent any leakage from back seat when it¡¯s opened. In option, HLC is making Welded Pipe Connection Extended Bonnet type. The materials of pipe should be Austenitic Stainless Steel. You can make choice according to service.
  • DESIGN
  • Basically, HLC¡¯s valves for cryogenic service is supplied with Heavy Wall Thickness Type based on API 600. This is to help valves have enough corrosion resistance and allowance compared with ASME B16.34. But according to customer¡¯s requirement, it¡¯s available with ANSI B16.34.
  • PACKING
  • Anti-exclusion square-braiding graphite fi ber top & bottom rings and pure graphite preformed packing to be provided all valves. In other option, there is PTFE but we can supply other materials considering using in cryogenic service.
  • APPLICAPABLE LIQUIFIED GASES
  • Anti-exclusion square-braiding graphite fi ber top & bottom rings and pure graphite preformed packing to be provided all valves
  • * Everything can be replaced the ones which is requested by customers¡¯ requirement
  • GASES BOILING POINT GASES BOILING POINT
    `C `F `C `F
    CARBON DIOXIDE -78.5 -109.0 OXYGEN(O2) -182.9 -296.0
    METHANE(CH4) -168.0 -270.0 ARGON -185.9 -303.0
    NATURAL GAS(LNG) -168.0 -270.0 NITROGEN(N2) -195.8 -320.0
    * Everything can be replaced the ones which is requested by customers¡¯ requirement